Wordspecs

Blog

Datasheet software for hardware startups: keep every product consistent

Private beta. Access is by waitlist, and paid plans open when the beta ends. Join the waitlist.

A hardware startup often ships its second product with a datasheet copied from the first. By the fourth product the tables use different units, the sections come in a different order and nobody is sure which revision a customer holds. Datasheet software prevents that drift by fixing the sections, the table columns and the notation, and by recording every revision.

What a datasheet needs

Where drift starts

Drift comes from copying an old file and editing it. A column is added to one table but not another, "mA" becomes "milliamps", a section moves. Each change is small, and together they make a product line look improvised.

The clearest case is one parameter written differently across a product line. Here are three datasheets for a fictional sensor family, TH-210, TH-215 and TH-230, all describing the same low-power state between measurements:

DatasheetName as writtenValue as writtenStandardized nameStandardized value
TH-210Sleep current0.4 uA typSupply current, sleep mode0.4 µA typ
TH-215Standby supply current400 nA typSupply current, sleep mode0.4 µA typ
TH-230Idd (idle)0.0004 mA typSupply current, sleep mode0.4 µA typ

The same value appears three ways. The rule that fixes it has three parts:

A worked electrical characteristics table

The table below is for TH-210, a fictional temperature and humidity sensor. Every value is invented for this example, and the values are internally consistent: in each row the minimum, typical and maximum are in order.

ParameterMinTypMaxUnitTest conditions
Supply voltage, VDD1.623.33.6VOperating range
Supply current, measurement-120180µAVDD = 3.3 V, TA = 25 °C, one measurement per second, average
Supply current, sleep mode-0.41.2µAVDD = 3.3 V, TA = 25 °C, between measurements
Relative humidity measurement range0-100%RHFull range, VDD = 3.3 V
Temperature measurement error-0.50.10.5°C15 to 40 °C ambient, VDD = 3.3 V
Measurement time-812msOne temperature and one humidity reading, VDD = 3.3 V

Notation rules that keep a table like this readable:

Revision history and naming

Each revision of TH-210 records the date, the change and why it matters to someone holding that revision.

RevisionDateWhat changedWhy it matters to a reader
Rev A2026-02-10First release. Sleep current typical 0.6 µA, maximum 1.5 µA.Baseline. Designs built on it carry the higher sleep figure.
Rev B2026-05-12Supply current, sleep mode: typical 0.6 µA to 0.4 µA, maximum 1.5 µA to 1.2 µA, after a firmware change.Battery-life estimates made from Rev A are pessimistic. Recalculate them with Rev B values.
Rev C2026-09-30Measurement time maximum 10 ms to 12 ms. Test conditions added to temperature measurement error.Timing budgets based on 10 ms need the new maximum. The added conditions show where the error figure applies.

Name the revision so a customer can tell which one they hold. Put the document ID and the letter together, for example TH-210-DS Rev C, on the cover and in the footer of every page. The footer matters because a single page can be printed or emailed on its own. Increase the letter for any change to a value, a condition, an ordering code or a requirement, including small corrections, so two different documents never share a letter. Keep the date in the history table rather than the name, because a date can mean a release date or a print date. The revision letter is not part of the part number: units sold in Rev A and Rev C have the same order code.

Ordering information

A TH-210 part number is built from codes read left to right: series, output, cable, then packaging. For example, TH-210-D-2-B is the TH-210 with I2C digital output, a 300 mm cable and bulk packaging.

SegmentCodeMeaning
SeriesTH-210Temperature and humidity module, documented in TH-210-DS
OutputDDigital output, I2C
OutputUDigital output, UART
Cable1Bare module, no cable
Cable2300 mm cable
Cable31 m cable
PackagingBBulk bag, 100 pcs
PackagingTTape and reel, 1000 pcs

Not every combination is stocked, so check the stocked list before quoting a customer. The revision letter never appears in the part number.

Pre-release checklist

  1. The document ID and revision letter appear on the cover and in every page footer.
  2. Every electrical row has a value or a dash. No cell is empty.
  3. Minimum, typical and maximum are in order in every row, and each value traces to a test report whose number is recorded in your internal file.
  4. Each row states its test conditions, including supply voltage and ambient temperature.
  5. Parameter names, units and symbols match the notation rules and the previous revision.
  6. Environmental and mechanical figures match the current drawing and the test records.
  7. Every ordering code decodes with the part-number table, and every stocked variant appears in it.
  8. Every changed value has a row in the revision history with the reason for the change.
  9. Section order and table columns match the template, not the previous document.
  10. Check the rules that apply to your product and market, and confirm the document contains whatever statements they require.
  11. Export the PDF and check the page numbers, the revision in the footer and the links.

Wordspecs for datasheets

Wordspecs includes a hardware datasheet template with electrical, environmental, mechanical and ordering fields. The TH-210 sample sheet (a fictional sensor) shows the layout. Saved templates let you keep your own table columns and wording for every product, and the Team plan adds shared templates and version history.

Related: which template fits which document.

Join the waitlist